https://doi.org/10.1140/epjcd/s2006-02-002-x
Scientific Note
Reconstruction of the signal amplitude of the CMS electromagnetic calorimeter
1
Laboratoire d’Annecy-le-Vieux de Physique des Particules, 74941, Annecy-le-Vieux, France
2
Institute of Nuclear Physics “Demokritos”, 153 10, Attiki, Greece
3
“Vinca” Institute of Nuclear Sciences and Faculty of Physics, University of Belgrade, 11000, Belgrade, Serbia and Montenegro
4
Northeastern University, Boston, MA, 02115-5096, USA
5
Bristol University, Bristol, BS8 1TL, UK
6
National Central University, Chung-Li, Taiwan
7
Delhi University, Delhi, 110 007, India
8
Rutherford Appleton Laboratory, CCLRC, Didcot, OX11 0QX, UK
9
Joint Institute for Nuclear Research, 141980, Dubna, Moscow Region, Russia
10
European Organization for Nuclear Research, CERN, 1211, Geneva 23, Switzerland
11
CEA/Saclay, 91191, Gif-sur-Yvette cedex, France
12
University of Ioannina, 451 10, Ioannina, Greece
13
Laboratório de Instrumentação e Física Experimental de Partículas, 1000-149, Lisboa, Portugal
14
Instituto de Engenharia de Sistemas e Computadores, 1000-029, Lisboa, Portugal
15
Imperial College, London, SW7 2BZ, UK
16
Brunel University, Middlesex, UB8 3PH, UK
17
Università degli Studi Milano-Bicocca and INFN-Sezione di Milano, 20126, Milano, Italy
18
University of Minnesota, Minneapolis, MN, 55455, USA
19
Research Institute for Nuclear Problems, Belorussian State University, 220050, Minsk, Belarus
20
Institute for Nuclear Research, Russian Academy of Sciences, 117312, Moscow, Russia
21
Lebedev Physical Institute, Russian Academy of Sciences, 117924, Moscow, Russia
22
Bhabha Atomic Research Centre, Mumbai, 400 085, India
23
Yale University, New Haven, CT, 06520-8121, USA
24
Cyprus University, 1678, Nicosia, Cyprus
25
Laboratoire Leprince-Ringuet, Ecole Polytechnique, 91128, Palaiseau Cedex, France
26
Charles C. Lauritsen Laboratory, California Institute of Technology, Pasadena, CA, 91125, USA
27
State Research Center, 142284, Protvino, Moscow Region, Russia
28
ENEA–CR Casaccia, 00060, S. Maria di Galeria, Roma, Italy
29
Dipartimento di Fisica and INFN-Sezione di Roma, Università “La Sapienza”, 00185, Roma, Italy
30
PMF, Split University, 21000, Split, Croatia
31
FESB, Technical University of Split, 21000, Split, Croatia
32
National Taiwan University, 106, Taipei, Taiwan
33
Dipartimento di Fisica and INFN-Sezione di Torino, Università di Torino, 10125, Torino, Italy
34
Dipartimento di Fisica and INFN-Sezione di Trieste, Università di Trieste, 34127, Trieste, Italy
35
Institut de Physique Nucléaire, IN2P3-CNRS and Université C. Bernard Lyon I, 69622, Villeurbanne, France
36
Paul Scherrer Institut, 5232, Villigen, Switzerland
37
Yerevan Physics Institute, 375036, Yerevan 36, Armenia
38
Institute for Particle Physics, ETH Zürich, 8093, Zürich, Switzerland
39
High Energy Physics Institute, Tblisi, Georgia
Received:
10
April
2006
Revised:
13
April
2006
Published online:
16
June
2006
The amplitude of the signal collected from the PbWO4 crystals of the CMS electromagnetic calorimeter is reconstructed by a digital filtering technique. The amplitude reconstruction has been studied with test beam data recorded from a fully equipped barrel supermodule. Issues specific to data taken in the test beam are investigated, and the implementation of the method for CMS data taking is discussed.
© Springer-Verlag, 2006